APPLICATIONS OF OHM'S LAW


APPLICATIONS OF OHM'S LAW




As an application of Ohm's law, any voltage V, current I or resistance R in an electrical circuit can be determined without actually measuring it if the two others values are known.

This law can be used to determine the amount of current I flowing in the circuit when voltage V is applied to resistance R. As stated previously, Ohm's law is:

Current = Voltage / Resistance.

In the following circuit, assume that resistance R is 2 and voltage V that is applied to it is 12 V. Then, current I flowing in the circuit can be determined as follows:

OHM'S LAW FORMULA

OHM'S LAW FORMULA



When voltage is applied to an electrical circuit, current flows in the circuit. The following special relationship exists among the voltage, current and resistance within the circuit: the size of the current that flows in a circuit varies in proportion to the voltage which is applied to the circuit, and in inverse proportion to the resistance through which it must pass. This relationship is called Ohm's law, and can be expressed as follows:

E = I R

Voltage = Current x Resistance
E Voltage applied to the circuit, in volts (V)

I Current flowing in the circuit, in amperes (A)

R Resistance in the circuit, in ohms



In practical terms "V = I x R" which means
"Voltage = Current x Resistance".

1 volt will push one amp through 1 ohm of resistance.

NOTE: E = IR, V=AR, or V=IR are all variations of the same formula. How you learned Ohm's law will determine which one you will use. Personal preference is the only difference; anyone will get you the correct answer.

Wednesday, June 2, 2010

Key Lock Switches

Key Lock Switches


Keylock switches are popular type of switches that are activated with the help of a key that is turned in a circle and can stop in a range of positions. The switching mechanism of these switches has features like self-cleaning, sliding contacts for providing high reliability, long operating life and a smooth operation. The bushing and housing of these switches is often constructed of fiberglass. Keylock switches are specially designed for meeting the needs of applications that require high reliability.

Keylock switches can be constructed either as a single deck or multi-deck. A single deck switch will have specifications for number of poles; and a multi-deck switch will have specifications for number of decks and number of poles per deck. The number of poles can be explained as the number of separate circuits that can be activated through a switch at any given time. The number of decks can be explained as the maximum number of decks that can be attached to a common actuating shaft.

The poles per deck can be explained as the number of separate circuits that can be activated through a switch at any given time per deck.

Materials of construction
Key lock switches are made from materials like plastic and metal. High quality materials are used for manufacturing the base and key of these switches.

Buying Tips for Key Lock Switches
There are certain physical, electrical and other specifications and parameters that buyers must consider while purchasing or selecting keylock switches. These specifications are:

* Physical specifications: These include:
o Angular distance: It is a distance measured in degrees between positions.
o Mechanical life: It is the maximum life expectancy of the switch.

* Electrical specifications: These include:
o Maximum current rating
o Maximum AC voltage rating
o Maximum DC voltage rating

* Stop Styles: These can be:
o Fixed: These come fixed from a manufacturer.
o Adjustable: These can be changed by the end user.
o Continuous: These have no stops.
* Contact styles: These include:
o Shorting: These are Make Before Break and thus, useful for preventing arcing during position change.
o Non-shorting: These are Break Before Make and thus, the switch opens the preceding circuit before closing the next.

* Terminal choices: These include:
o Wire leads
o Solder terminals
o Screw terminals
o PCB pins

* Keylock Certifications: These include
o CE certification
o CSA certification
o UL listed
o An important environmental parameter that must be considered while selecting key lock switches is the operating temperature.

* Applications
These switches are generally used in high security applications including:
o Computer/peripherals and communication
o Instrumentation
o Industrial/commercial
o Medical equipment

Monday, May 31, 2010

Contactor


Contactor



In semiconductor testing, contactor can also refer to the specialised socket that connects the device under test.
In process industries a contactor is a vessel where two streams interact, for example, air and liquid.

A contactor is an electrically controlled switch (a relay) used for switching a power or control circuit.[1] A contactor is controlled by a circuit which has a much lower power level than the switched circuit. Contactors come in many forms with varying capacities and features. Unlike a circuit breaker, a contactor is not intended to interrupt a short circuit current.

Contactors range from those having a breaking current of several amps and 24 V DC to thousands of amps and many kilovolts. The physical size of contactors ranges from a device small enough to pick up with one hand, to large devices approximately a meter (yard) on a side.

Contactors are used to control electric motors, lighting, heating, capacitor banks, and other electrical loads.
Contents
[hide]

* 1 Construction
* 2 Operating principle
* 3 Ratings
* 4 Applications
o 4.1 Lighting control
o 4.2 Magnetic starter
* 5 References

[edit] Construction
Albright SPST DC contactor,
sometimes used in EV conversions

A contactor is composed of three different items. The contacts are the current carrying part of the contactor. This includes power contacts, auxiliary contacts, and contact springs. The electromagnet provides the driving force to close the contacts. The enclosure is a frame housing the contact and the electromagnet. Enclosures are made of insulating materials like Bakelite, Nylon 6, and thermosetting plastics to protect and insulate the contacts and to provide some measure of protection against personnel touching the contacts. Open-frame contactors may have a further enclosure to protect against dust, oil, explosion hazards and weather.

High voltage contactors (greater than 1000 volts) may use vacuum or an inert gas around the contacts.

Magnetic blowouts use blowout coils to lengthen and move the electric arc. These are especially useful in DC power circuits. AC arcs have periods of low current, during which the arc can be extinguished with relative ease, but DC arcs have continuous high current, so blowing them out requires the arc to be stretched further than an AC arc of the same current. The magnetic blowouts in the pictured Albright contactor (which is designed for DC currents) more than double the current it can break, increasing it from 600 A to 1,500 A.

Sometimes an economizer circuit is also installed to reduce the power required to keep a contactor closed; an auxiliary contact reduces coil current after the contactor closes. A somewhat greater amount of power is required to initially close a contactor than is required to keep it closed. Such a circuit can save a substantial amount of power and allow the energized coil to stay cooler. Economizer circuits are nearly always applied on direct-current contactor coils and on large alternating current contactor coils.

A basic contactor will have a coil input (which may be driven by either an AC or DC supply depending on the contactor design). The coil may be energized at the same voltage as the motor, or may be separately controlled with a lower coil voltage better suited to control by programmable controllers and lower-voltage pilot devices. Certain contactors have series coils connected in the motor circuit; these are used, for example, for automatic acceleration control, where the next stage of resistance is not cut out until the motor current has dropped.[2]
[edit] Operating principle

Unlike general-purpose relays, contactors are designed to be directly connected to high-current load devices. Relays tend to be of lower capacity and are usually designed for both normally closed and normally open applications. Devices switching more than 15 amperes or in circuits rated more than a few kilowatts are usually called contactors. Apart from optional auxiliary low current contacts, contactors are almost exclusively fitted with normally open contacts. Unlike relays, contactors are designed with features to control and suppress the arc produced when interrupting heavy motor currents.

When current passes through the electromagnet, a magnetic field is produced, which attracts the moving core of the contactor. The electromagnet coil draws more current initially, until its inductance increases when the metal core enters the coil. The moving contact is propelled by the moving core; the force developed by the electromagnet holds the moving and fixed contacts together. When the contactor coil is de-energized, gravity or a spring returns the electromagnet core to its initial position and opens the contacts.

For contactors energized with alternating current, a small part of the core is surrounded with a shading coil, which slightly delays the magnetic flux in the core. The effect is to average out the alternating pull of the magnetic field and so prevent the core from buzzing at twice line frequency.

Most motor control contactors at low voltages (600 volts and less) are air break contactors; i.e., ordinary air surrounds the contacts and extinguishes the arc when interrupting the circuit. Modern medium-voltage motor controllers use vacuum contactors.

Motor control contactors can be fitted with short-circuit protection (fuses or circuit breakers), disconnecting means, overload relays and an enclosure to make a combination starter.
[edit] Ratings

Contactors are rated by designed load current per contact (pole),[3] maximum fault withstand current, duty cycle, voltage, and coil voltage. A general purpose motor control contactor may be suitable for heavy starting duty on large motors; so-called "definite purpose" contactors are carefully adapted to such applications as air-conditioning compressor motor starting. North American and European ratings for contactors follow different philosophies, with North American general purpose machine tool contactors generally emphasizing simplicity of application while definite purpose and European rating philosophy emphasizes design for the intended life cycle of the application.

Current rating of the contactor depends on utilization category. For example IEC Categories are described as:

* AC1 - Non-inductive or slightly inductive rows
* AC2 - Starting of slip-ring motors
* AC3 - Starting of squirrel-cage motors and switching off only after the motor is up to speed. (Make Locked Rotor Amps (LRA), Break Full Load Amps (FLA))
* AC4 - Starting of squirrel-cage motors with inching and plugging duty. Rapid Start/Stop. (Make and Break LRA)
* AC11 - Auxiliary (control) circuits

[edit] Applications
[edit] Lighting control

Contactors are often used to provide central control of large lighting installations, such as an office building or retail building. To reduce power consumption in the contactor coils, latching contactors are used, which have two operating coils. One coil, momentarily energized, closes the power circuit contacts, which are then mechanically held closed; the second coil opens the contacts.
[edit] Magnetic starter

A magnetic starter is a contactor designed to provide power to electric motors. The magnetic starter has an overload relay, which will open the control voltage to the starter coil if it detects an overload on a motor.[4][5] Overload relays may rely on heat produced by the motor current to operate a bimetal contact or release a contact held closed by a low-melting-point alloy. The overload relay opens a set of contacts that are wired in series with the supply to the contactor feeding the motor. The characteristics of the heaters can be matched to the motor so that the motor is protected against overload. Recently, microprocessor-controlled motor protection relays offer more comprehensive protection of motors.